XY-J04 timer with delay switch
XY-J04 timer with delay switch
Trigger cycle delay switch circuit double MOS tube control board instead of relay module 12 24 v
0.1 second (min) ~ 999 min (max) continuously tunable
Module features and applications:
Module highlights:
Wake-up by a test;
Work model:
P1 mode: after the signal is activated, the relay conducts ON time and then disconnects; in OP time, the following operations are performed.
P1.1: signal again trigger invalid
P1.2: the signal triggers the time again
P1.3: the signal is reactivated, the relay is disconnected, and the timer has stopped.
P-2: activate signal, the relay breaks the CL time, the relay conducts ON time, and after the timer is complete, the relay is disconnected.
P3.1: after the trigger signal is activated, the relay opens the time of OP, the relay breaks the CL time, and then the above action circulates, the relay is given the signal again, the relay is disconnected and the timing is stopped ; the cycle times (LOP) can be set;
P3.2: after power on, there is no need to trigger the signal, the relay can lead ON time, the relay breaks CL time, circulate the above actions, and the number of cycles (LOP) can be set.
P-4: if the signal has a trigger signal, the timing is zero, the relay is kept open; when the signal disappear, the relay is broken after the time of time ON; during the time of time, the signal is repeated and the time is zero;
Product parameters:
1: working voltage: DC 5V - 36V;
2: trigger signal source: high level trigger (DC 3.0 v-24 v) signal and system do not share common ground to improve the anti-jamming ability of the system.
3: output power: DC DC 5V - 36V, constant current 15A at room temperature, power 400 w! Under the condition of additional heat dissipation, the maximum current can reach 30A.
4: static current: 15 mA
5: service life: infinite switch; working temperature: -40-85 C; size: 6.0 * 3.4 * 1.2 cm
6: with optocoupler isolation, anti-interference ability, industrial grade circuit boards, set parameters after power failure lasting memory.
Special attention:
The module is active electrified output, and the output (load side) voltage equal to the input voltage (DC 5V - 36V).
The 'DC +' and the load '+' poles themselves are internal short connections, but the DC 'and load' - 'poles cannot be short connected during use, otherwise the load will not be checked to open and turn on, Equal to the tax that is all the time.
Time range
0.1 second (min) ~ 999 min (max) continuously tunable
How the time range:
After setting the parameter values in the mode selection interface, select the time range by briefly pressing the STOP key.
XXX. comma in bit, time range: 1 second ~ 999 sec.
XXX the comma is clear. The time range is 1 minutes ~ 999 minutes.
For example, if you want to set OP 3.2 seconds, move the comma to ten bits, and the digital tube displays 3.2.
Parameter Description: ON lead time, CL disconnection, LOP cycle number (1 to 999 times, "---" represents infinite cycle).
These parameters are independent of each other, but each pattern shares these parameters, for example, in the P1.1 setting the adjust time ON is 5 seconds, the user wants to switch to the P1.2 mode, then the ON will be 5 seconds when the corresponding parameters are set in the P1.2;
On the main interface (display 000), short on SET button will display ON (CL, LOP) and the corresponding time XXX;
If there is only OP (for example, mode P1.1, P1.2, P1.3) in the cartridge, then the short SET key leaves only OP and the corresponding time.
If there is OP, CL and LOP (for example, mode P3.1, P3.2) in the pattern, the short press of SET key will display ON and corresponding time, CL and corresponding time, LOP and corresponding times;
After setting up the mode, you can easily view the parameters in the current mode by briefly pressing the SET key in the main interface, which is very convenient.
How parameters
Main interface: relay not working state display "000" (no comma), relay working state with decimal point, very clear!
Mode selection interface: long press SET key to, after setting up, long press SET key to exit, back to main interface, very easy!
STOP key function extension:
Relay enabled mode:
The relay is transmitted in the 1. OP: OP conduction time.
In the main interface, press STOP button to switch between ON and OFF. The current state will blink and then return to the main interface. (this function is emergency stop function, a key breaks closed relay).
Sleep pattern:
On the STOP button for 2 seconds turn the CP and Od status.